Only values with a real mapped source belong here.
- Select the correct machine family and axis configuration before interpreting signals or parameters.
- Confirm mode, interface, protocol and connection state.
- Unmapped values remain N/A.
- Do not interpret overview values as controller truth unless their source is identified.
Machine Overview
ACNC for Android BETA
Installation
- Download the APK on the phone (or copy it to the phone).
- Open the file and allow installing apps from this source when Android asks.
- Open ACNC → Continue → Devices.
- Connect the USB serial adapter with an OTG adapter, press Refresh, then Request permission.
Machine State
Quick Actions
Device Capability
Mobile / Laptop
Devices — Guideline
See the complete chain from this phone/computer to the machine. Only real, detected hardware is shown.
- Connect the USB serial adapter (on a phone via USB-OTG) and press Scan devices.
- In a desktop browser use Request serial port; on Android use the ACNC Bridge app and allow USB permission.
- Select the physical interface, serial settings and target profile from machine documentation — ACNC never guesses them.
- Run the Connection test to see which step fails. No data is ever written automatically.
Connection chain
UsbManager devices: –
| Name | VID | PID | Class | Subclass | Protocol | Interfaces | Category | Serial driver match | Driver | Permission | Port open | State |
|---|
Native hardware log
| Timestamp | Event | Details |
|---|
Hardware access / installation status
Target device profile
| # | Stage | Result | Detail |
|---|
Driver status (registry)
| Family | VID | Known PIDs | Android | Linux | Windows | Status |
|---|
| Timestamp | Event | Transport | Device | Driver | Result | Detail |
|---|
Terminal — Guideline
Use raw serial communication only after verifying port settings.
- Connect a supported adapter.
- Choose ASCII or HEX deliberately.
- Do not send undocumented commands to a production machine.
- Export logs before risky troubleshooting.
01 03 00 00 00 01 84 0A. A valid Modbus write frame typed here is refused unless the safety mode is DANGEROUS. Sending is blocked while a Modbus transaction waits for its response.Control lines
Capture
Protocols — Guideline
Configure RS232/RS485 and Modbus RTU from known machine documentation.
- Verify baud, data bits, stop bits and parity.
- RS485 requires a compatible physical adapter.
- Use one Modbus transaction at a time.
- Writes require explicit enable and confirmation.
RS232 / RS485
Modbus RTU
Native / Future
Register Data
| # | Address | Decimal | HEX | Status |
|---|
Signals — Guideline
Build a normalized signal map from observed, documented or imported data.
- Record source and address.
- Separate confirmed signals from hypotheses.
- Correlation is evidence, not proof of causality.
| Name | Type | Source | Address | Value | Unit | Sampling | Frequency | Confidence |
|---|
Signal Relationships
Classification
Relevant signal candidates for this machine type
I/O Map — Guideline
Document physical and logical I/O with traceable evidence.
- Record DI/DO/AI/AO/BUS/VIRTUAL type.
- Add connector/terminal and electrical level where known.
- Record normal and fault states only when verified.
| Name | Type | Direction | Address | Connector | Level | Normal | Fault | Function | Confidence |
|---|
Parameters — Guideline
Inspect and reconstruct parameters without assuming suspicious values are automatically corrupted.
- Verify datatype, scaling and unit.
- 65535 / 0xFFFF can have several meanings.
- Keep source and confidence for every proposal.
- Before write: read old value, confirm, write, re-read and verify.
| Name | Group | Address | Current | Unit | Datatype | Source | Confidence | Status | Proposed | Action |
|---|
Parameter groups for this machine
Write Policy
Example
Advanced reconstruction & shadow — ACNC Next
This free demo intentionally stops at reading, decoding and basic diagnostics of what the controller already exposes. The following capabilities require stronger guarantees around verification, traceability and support, and are part of ACNC Next (proprietary, developed by Dromation in cooperation with Kovigal d.o.o.) rather than this public edition:
- Axis scaling reconstruction — deriving encoder scale/soft limits from supervised measurements, with regression and outlier analysis.
- Per-axis reconstruction records — tracked source, confidence and verification state for engineer-entered axis configuration.
- Logical Shadow — a parameter/I-O/calibration/firmware shadow snapshot of the machine's configuration.
- Machine Configuration Package — building and exporting a consolidated, reusable configuration artifact.
What this demo still gives you on this machine: parameter/signal/I-O mapping, suspicious-value flagging, the read-only Controller State Reader, and local consistency diagnostics — see Parameters, Reader and Diagnostics.
Auto Communication Discovery — Guideline
ACNC finds and ranks the most likely line settings by itself. You do not have to guess baud rate, parity, stop bits or flow control.
- Connect the adapter (USB-OTG on Android). Select it on the Devices screen if several are attached.
- Press AUTO DISCOVER. ACNC opens, listens and closes the port for every setting — nothing is sent.
- Only with documented read-only requests (controller profile or State Reader) a short active read stage follows.
- Use the best candidate, check it against the controller documentation, then save it as an Initiation Map.
Auto communication discovery
Discovery settings
Documented Modbus read for the active stage (optional)
| # | Setting | Stage | RX | Frames | Valid | ASCII | CTS/DSR/DCD | Score | Confidence | Fault |
|---|
Raw RX during discovery
Initiation Map
| Name | Device | Serial | Confidence | This device |
|---|
Fault tree — panel shows state but ACNC cannot read it
Discovery FMEA
| Failure mode | Cause | Effect | Detection | Mitigation | S | O | D | RPN |
|---|
Controller State Reader — Guideline
Read the existing controller state only. Nothing on the machine is modified.
- Connect the adapter (Devices) with the settings from the controller documentation.
- Start with PASSIVE READ — ACNC transmits nothing and shows every received byte.
- Only if the controller is silent: ACTIVE READ ONLY with Modbus FC01–FC04 or documented read commands.
- Values without documentation stay raw. Never assume datatypes or scaling.
Mode
Read method
RS485 transport
Status
Diagnostic counters
| Time | Dir | Slave | FC | Address | Qty | Data | CRC |
|---|
Modbus read-only master
Documented read commands (controller profile)
| Name | HEX | Reference |
|---|
| Field | Value | Source | Timestamp | Confidence | Verification |
|---|
Registers read / observed (raw)
| Slave | FC | Address | Raw | HEX | Source | Timestamp |
|---|
Alarms · I/O · Drives
Auto communication discovery
Read-only log
| Time | Operation | Protocol | Result | Reason |
|---|
Fault tree — controller state not available
State Reader FMEA
| Failure mode | Cause | Effect | Detection | Mitigation | S | O | D | RPN |
|---|
Diagnostics — Guideline
Use FTA and FMEA to structure troubleshooting and prevent premature conclusions.
- Start from the observed symptom.
- Link alarms, signals and parameters.
- Keep hypotheses separate from verified causes.
- Record the next safe test.
Fault Tree Analysis
FMEA
| Failure mode | Effect | Detection | Prevention |
|---|---|---|---|
| Wrong axis scaling | Wrong movement distance | Measured displacement | Multi-point verification |
| Wrong datatype | Extreme value | Range validation | Typed map |
Diagnostic Findings
Connection FMEA
| Failure mode | Cause | Effect | Detection | Mitigation | S | O | D | RPN |
|---|
Sessions — Guideline
Maintain traceability of engineering work.
- Log connection changes and communication.
- Export important sessions before configuration changes.
- Avoid unnecessary personal/confidential information.
| Timestamp | Type | Direction | Protocol | Details |
|---|
Settings & Privacy — Guideline
Review local processing, privacy and deployment behavior.
- Machine communication remains local in this static build.
- Support uses user-initiated webmail / mail app / EML export.
- Privacy acknowledgement never authorizes machine writes.
Language
ACNC for Android BETA
Installation
- Download the APK on the phone (or copy it to the phone).
- Open the file and allow installing apps from this source when Android asks.
- Open ACNC → Continue → Devices.
- Connect the USB serial adapter with an OTG adapter, press Refresh, then Request permission.
License
ACNC Web demo and ACNC for Android are freeware demo editions — © Dromation, developed in cooperation with Kovigal d.o.o. Free for personal, non-commercial and educational use; commercial use requires an agreement with Dromation.
Hardware access / installation status
Machine types
Local / Online
Support
Privacy / GDPR
This in-app summary complements the full privacy notice shown before the application starts.
Demo version
This is a demonstration version of ACNC, developed by Dromation in cooperation with Kovigal d.o.o.
Local processing
Supported machine communication, local logs, local image previews and engineering exports are designed to remain on the user’s device unless deliberately shared.
GDPR rights
Where GDPR applies, relevant rights may include information, access, rectification, erasure, restriction, portability, objection, withdrawal of consent where consent is the legal basis, and the right to complain to a competent supervisory authority.
Engineering separation
Privacy acceptance does not authorize writes, movement, PLC changes, firmware changes or controller-memory modification.